THE CUSTOMER
Preform manufacturer
HTS SOLUTION
iTherm manifold with continuous transitions and fewer splits for controlled, symmetric flow.
THE CHALLENGE
Balanced filling, faster material change and lower pressure drop.
OUTCOME
50% improvement in filling balance
Case study overview
THE CHALLENGE: Conventional drilled-channel design caused non-uniform filling. Multiple 90° splits (2 → 2 → 3) created too many subdivisions, broke symmetry, and limited flow control.
HTS SOLUTION: HTS introduced continuous transitions, eliminating 90° angles. Flow was split directly 2 → 6, reducing subdivisions and ensuring controlled, symmetric distribution.
HTS and the customer iterated multiple designs, all supported by simulation and direct comparison of results. Step by step, the geometry was refined until the final optimized design was achieved, as shown in the figures, delivering measurable improvements in uniformity, efficiency, and reliability.
Outcome
- Filling imbalance cut from 0.88% → 0.41% (>50% improvement).
- Pressure drop reduced by 11%, improving flow efficiency in the hot-runner manifold.
- Shear stress reduced by 9%, lowering material degradation and extending manifold life.